{"product_id":"steel-fire-system-sensor-i3-photoelectric-thermal-combination-detector","title":"System Sensor i3 Photoelectric \/ Thermal Combination Detector","description":"\u003cp\u003eThe System Sensor i3 photo\/thermal combination detector pairs a photoelectric smoke chamber with a 135°F (57.2°C) fixed heat sensor in one conventional plug-in head, and the mounting base comes in the box. SupplyNow offers it through Steel Fire Equipment for fire alarm contractors, service companies and building managers across the GTA and Canada.\u003c\/p\u003e\u003cp\u003ePick the 2-wire version (C2WTR-BA) for initiating circuits that power the detector, or the 4-wire version (C4WTR-BA) where a separate power pair is run. Both models run on 12 or 24 V, are not polarity sensitive and include a Form C relay for auxiliary functions.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePhotoelectric smoke sensing combined with a fixed 135°F (57.2°C) heat element\u003c\/li\u003e\n\u003cli\u003eForm C auxiliary relay rated 2 A at 30 V AC\/DC on both versions\u003c\/li\u003e\n\u003cli\u003eFreeze warning: the head reports trouble when the room drops to about 41°F (5°C)\u003c\/li\u003e\n\u003cli\u003eDrift compensation and signal smoothing help cut down on nuisance alarms\u003c\/li\u003e\n\u003cli\u003eRed and green status LEDs show normal standby, out-of-sensitivity, freeze trouble and alarm\u003c\/li\u003e\n\u003cli\u003eRemovable cover and smoke chamber make cleaning easier; base has in-line terminals\u003c\/li\u003e\n\u003cli\u003e2-wire model can send a remote maintenance signal when used with a C2W-MOD2A module or an i3 Ready panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv data-sn=\"specs\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003ctd\u003ePhotoelectric \/ Thermal Combination Smoke Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eSystem Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMfr. Model #\u003c\/th\u003e\n\u003ctd\u003eC2WTR-BA, C4WTR-BA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003ei3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eC2WTR-BA (2-wire), C4WTR-BA (4-wire, Form C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensing\u003c\/th\u003e\n\u003ctd\u003ePhotoelectric smoke plus 135°F (57.2°C) fixed heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Voltage\u003c\/th\u003e\n\u003ctd\u003e12\/24 V, non-polarized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Range\u003c\/th\u003e\n\u003ctd\u003e8.5–35 V (2-wire); 10–35 V (4-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandby Current\u003c\/th\u003e\n\u003ctd\u003e50 µA max. average\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm Current\u003c\/th\u003e\n\u003ctd\u003e130 mA max., panel limited (2-wire); 35 mA (4-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelay Rating\u003c\/th\u003e\n\u003ctd\u003eForm C, 2 A at 30 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Sensitivity\u003c\/th\u003e\n\u003ctd\u003e2.5 %\/ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFreeze Trouble Point\u003c\/th\u003e\n\u003ctd\u003e41°F (5°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e32–100°F (0–37.8°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity\u003c\/th\u003e\n\u003ctd\u003e0–95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSize With Base\u003c\/th\u003e\n\u003ctd\u003e5.3 in (134 mm) dia. x 2.0 in (51 mm) high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e7.1 oz (200 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWire Gauge\u003c\/th\u003e\n\u003ctd\u003e14–22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003cdiv data-sn=\"literature\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/9387\/2943\/files\/system-sensor-c2wtr-ba-data-sheet.pdf?v=1795483336\" target=\"_blank\" rel=\"noopener\"\u003eSystem Sensor i3 Sounder and Relay Detectors Data Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Steel Fire Equipment Ltd","offers":[{"title":"2-Wire","offer_id":67804861530361,"sku":"C2WTRBA","price":188.11,"currency_code":"CAD","in_stock":true},{"title":"4-Wire, Form C","offer_id":67804861563129,"sku":"C4WTR-BA","price":238.3,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0061\/9387\/2943\/files\/C2WTRBA.png?v=1795471176","url":"https:\/\/www.supplynow.ca\/products\/steel-fire-system-sensor-i3-photoelectric-thermal-combination-detector","provider":"Supplynow Limited","version":"1.0","type":"link"}