{"title":"Fire Alarm Control Panels","description":"\u003cp\u003eConventional fire alarm control panels and releasing panels.\u003c\/p\u003e","products":[{"product_id":"steel-fire-fire-alarm-panel-6-zone-red-door","title":"Fire Alarm Panel, 6 Zone, Red Door","description":"\u003cp\u003eThe Mircom FA-106R is a six-zone conventional fire alarm control panel in a red cabinet, built on one circuit board and meant for non-coded alarm systems in smaller commercial, industrial and institutional buildings.\u003c\/p\u003e\u003cp\u003eSix Class B detection zones and two Class B signal circuits cover a typical small-building layout, and the on-board alarm and trouble relays make it easy to tie in other building systems. It suits fire alarm contractors and facility managers replacing or installing a small ULC-listed panel. Supplied through Steel Fire Equipment.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSix supervised Class B (Style Y) initiating zones for 2-wire detectors and pull stations\u003c\/li\u003e\n\u003cli\u003eTwo Class B signal circuits rated 1.25 A each, 2.0 A combined\u003c\/li\u003e\n\u003cli\u003eSteady or Temporal Code tones chosen by DIP switch, with a selectable one-minute silence inhibit\u003c\/li\u003e\n\u003cli\u003eForm C common alarm and common trouble relays, 3 A at 28 VDC resistive\u003c\/li\u003e\n\u003cli\u003eRegulated 24 VDC auxiliary output (250 mA) for an RTI-1 remote trouble indicator or 4-wire detectors\u003c\/li\u003e\n\u003cli\u003eRed cabinet with hinged door, fire-retardant Lexan window and CAT-30 lock\u003c\/li\u003e\n\u003cli\u003eRoom for 5 to 7 Ah standby batteries\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAccessories \u0026amp; Replacement Parts\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-remote-trouble-indicator\"\u003eRTI-1\u003c\/a\u003e – Remote trouble indicator\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-end-of-line-resistor-plate-3-9k\"\u003eMP-300\u003c\/a\u003e – 3.9K end-of-line resistor plate\u003c\/li\u003e\n\u003cli\u003eFA-102TR – Trim ring for flush mounting\u003c\/li\u003e\n\u003cli\u003eBAT-12V5A \/ BAT-12V7A – Standby batteries, 5 Ah \/ 7 Ah\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv data-sn=\"specs\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003ctd\u003eConventional Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eMircom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMfr. Model #\u003c\/th\u003e\n\u003ctd\u003eFA-106R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInitiating Zones\u003c\/th\u003e\n\u003ctd\u003e6, Class B (Style Y)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSignal Circuits\u003c\/th\u003e\n\u003ctd\u003e2, Class B (Style Y), 1.25 A each at 49°C, 2.0 A total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAuxiliary Power\u003c\/th\u003e\n\u003ctd\u003e24 VDC regulated, 250 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelays\u003c\/th\u003e\n\u003ctd\u003eForm C common alarm + common trouble, 3 A at 28 VDC resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAC Input\u003c\/th\u003e\n\u003ctd\u003e120 VAC 60 Hz 1 A or 240 VAC 50 Hz 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery\u003c\/th\u003e\n\u003ctd\u003e24 VDC (two 12 V), 5 to 7 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCharging Current\u003c\/th\u003e\n\u003ctd\u003e0.67 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eZone Loop Resistance\u003c\/th\u003e\n\u003ctd\u003e100 ohms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnd-of-Line Resistor\u003c\/th\u003e\n\u003ctd\u003e3.9K ohm, 1\/2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Environment\u003c\/th\u003e\n\u003ctd\u003eIndoor dry locations, 0 to 49°C, up to 93% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e347 x 322 x 71 mm (13.7 x 12.7 x 2.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCabinet Colour\u003c\/th\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003eULC (S527)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003cdiv data-sn=\"literature\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/9387\/2943\/files\/mircom-fa-106-catalogue-sheet.pdf?v=1795485941\" target=\"_blank\" rel=\"noopener\"\u003eMircom FA-106 Catalogue Sheet (CAT-5005) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/9387\/2943\/files\/mircom-fa-106-installation-manual.pdf?v=1795485941\" target=\"_blank\" rel=\"noopener\"\u003eMircom FA-103 \/ FA-106 Installation Manual (LT-1200) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Steel Fire Equipment Ltd","offers":[{"title":"Default Title","offer_id":67804842000633,"sku":"FA-106R","price":971.19,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0061\/9387\/2943\/files\/FA-106R.png?v=1795471108"},{"product_id":"steel-fire-mircom-fa-1000-series-conventional-fire-alarm-control-panel","title":"Mircom FA-1000 Series Conventional Fire Alarm Control Panel","description":"\u003cp\u003eThe Mircom FA-1000 Series is a conventional fire alarm control panel family with eight Class B (four Class A) initiating circuits and four indicating circuits on the main chassis, set up from the front panel with push buttons and DIP switches.\u003c\/p\u003e\u003cp\u003eChoose the 6 A eight-zone starter kit for smaller jobs, or a 12 A chassis expandable to 24 or 72 display points with plug-in adder modules. It is a good fit for fire alarm contractors serving schools, offices and mid-size commercial buildings across Canada. Supplied through Steel Fire Equipment.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEight Class B or four Class A initiating circuits (Style B \/ Style D), each set as alarm, supervisory, waterflow or trouble\u003c\/li\u003e\n\u003cli\u003e4 Class A\/B (Style Z\/Y) indicating circuits; each can be set silenceable or non-silenceable\u003c\/li\u003e\n\u003cli\u003eAudible patterns: March Time, Temporal Code, California Code or Steady\u003c\/li\u003e\n\u003cli\u003eTwo-stage operation and one-person walk test\u003c\/li\u003e\n\u003cli\u003eCommon alarm, supervisory and trouble relays, Form C, 1 A at 28 VDC\u003c\/li\u003e\n\u003cli\u003eRemovable door and terminal blocks for easier installation\u003c\/li\u003e\n\u003cli\u003eRS-485 link for RA-1000 remote annunciators\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eIncluded\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFA1008KADS: 8 Zone Starter Kit with MCC-1024-6ADS 6 A chassis, UB-1024DS backbox and DOX-1024DS white door\u003c\/li\u003e\n\u003cli\u003eMCC-1024-12ADS: 12 A main chassis, up to 24 display points (mounts in UB-1024DS)\u003c\/li\u003e\n\u003cli\u003eMCC-1024-12XTDS: 12 A main chassis, up to 72 display points (mounts in BBX-1024XT)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eModules \u0026amp; Accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-8-class-b-4-class-a-initiating-circuit-module\"\u003eDM-1008A\u003c\/a\u003e – 8 Class B \/ 4 Class A initiating circuit module\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-8-programmable-relay-circuit-module\"\u003eRM-1008A\u003c\/a\u003e – 8 programmable relay module\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-pr-300-polarity-reversal-city-tie-module\"\u003ePR-300\u003c\/a\u003e – Polarity reversal \/ city tie module\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-mircom-ram-1000-led-remote-annunciator\"\u003eRAM-1032TZDS\u003c\/a\u003e – Remote LED annunciator\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-mircom-ram-1000-led-remote-annunciator?variant=67804845211897\"\u003eRAX-1048TZDS\u003c\/a\u003e – 48-point remote LED annunciator\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-master-graphic-driver-board\"\u003eMGD-32\u003c\/a\u003e – Master graphic driver board\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-semi-flush-backbox-for-series-1000-annunciators\"\u003eBB-1001D\u003c\/a\u003e – Annunciator backbox\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-end-of-line-resistor-plate-3-9k\"\u003eMP-300\u003c\/a\u003e – 3.9K end-of-line resistor plate\u003c\/li\u003e\n\u003cli\u003eSGM-1004S – Four-circuit NAC module with synchronization\u003c\/li\u003e\n\u003cli\u003eUDACT-300A – Digital alarm communicator\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv data-sn=\"specs\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003ctd\u003eConventional Fire Alarm Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eMircom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMfr. Model #\u003c\/th\u003e\n\u003ctd\u003eFA1008KADS, MCC-1024-12ADS, MCC-1024-12XTDS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003ctd\u003eFA-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInitiating Circuits\u003c\/th\u003e\n\u003ctd\u003eClass B: 8 (Style B); Class A: 4 (Style D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIndicating Circuits\u003c\/th\u003e\n\u003ctd\u003e4 Class A\/B (Style Z\/Y)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e6 A (FA1008KADS); 12 A (MCC-1024-12ADS, MCC-1024-12XTDS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIndicating Circuit Rating\u003c\/th\u003e\n\u003ctd\u003e5 A max. (6 A unit); 10 A max. (12 A units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery Charging\u003c\/th\u003e\n\u003ctd\u003e10-24 Ah (6 A); 17-40 Ah (12 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay Points\u003c\/th\u003e\n\u003ctd\u003eUp to 24 (ADS models); up to 72 (XTDS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAdder Modules\u003c\/th\u003e\n\u003ctd\u003eUp to 2 (ADS) or 8 (XTDS), plus one PR-300 or UDACT-300A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmoke Detector Power\u003c\/th\u003e\n\u003ctd\u003e2 outputs, 200 mA max. each\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelays\u003c\/th\u003e\n\u003ctd\u003eCommon alarm, supervisory, trouble; Form C, 28 VDC 1 A resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure (W x H x D)\u003c\/th\u003e\n\u003ctd\u003eUB-1024DS: 14.5 x 26 x 4.2 in.; BBX-1024XT: 14.5 x 35.5 x 5.25 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListing\u003c\/th\u003e\n\u003ctd\u003eUL 864, 9th edition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003cdiv data-sn=\"literature\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/9387\/2943\/files\/mircom-fa-1000-catalogue-sheet.pdf?v=1795485941\" target=\"_blank\" rel=\"noopener\"\u003eMircom FA-1000 Series Catalogue Sheet (CAT-5620) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/9387\/2943\/files\/mircom-fa-1000-auxiliary-modules-catalogue-sheet.pdf?v=1795485941\" target=\"_blank\" rel=\"noopener\"\u003eMircom FA-1000 Series Auxiliary Modules Catalogue Sheet (CAT-5624) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Steel Fire Equipment Ltd","offers":[{"title":"8 Zone Starter Kit, 6A","offer_id":67804842426617,"sku":"FA1008KADS","price":2802.1,"currency_code":"CAD","in_stock":true},{"title":"8-24 Zone, 12A, 24 display points","offer_id":67804842459385,"sku":"MCC-1024-12ADS","price":2498.59,"currency_code":"CAD","in_stock":true},{"title":"8-72 Zone, 12A, 72 display points","offer_id":67804842492153,"sku":"MCC-1024-12XTDS","price":3236.24,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0061\/9387\/2943\/files\/MCC-1024-12ADS.png?v=1795471109"},{"product_id":"steel-fire-mircom-fr-320-6-zone-releasing-panel","title":"Mircom FR-320 6 Zone Releasing Panel","description":"\u003cp\u003eThe Mircom FR-320 is a releasing control panel for deluge, pre-action and clean agent suppression systems. It has six Class B inputs and four outputs, two of which can drive releasing solenoids.\u003c\/p\u003e\u003cp\u003eFourteen pre-set operating modes, adjustable release, manual-release and soak timers, plus cross-zone and counting-zone logic, let sprinkler and suppression contractors match the panel to the hazard. Available with a red or white door. Supplied through Steel Fire Equipment.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eField configurable for deluge, pre-action and agent release; can protect two hazard areas\u003c\/li\u003e\n\u003cli\u003eSix Class B inputs; add the ICAC-306 to run them as Class A\u003c\/li\u003e\n\u003cli\u003eFour Class B (Style Y) outputs, 1.7 A each and 5 A total; outputs 3 and 4 can be releasing circuits\u003c\/li\u003e\n\u003cli\u003eRelease timer 0 to 60 s, manual release delay 0 to 30 s, soak timer 0 to 15 min\u003c\/li\u003e\n\u003cli\u003eAbort options: standard UL, IRL, NYC or local jurisdiction\u003c\/li\u003e\n\u003cli\u003eCommon alarm, auxiliary alarm, common supervisory and common trouble relays\u003c\/li\u003e\n\u003cli\u003e14 pre-configured modes set with the CFG-300 tool\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eModules \u0026amp; Accessories\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-series-300-input-class-a-converter-module-6-circuits\"\u003eICAC-306\u003c\/a\u003e – Input Class A converter, 6 circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-six-relay-circuit-adder-module\"\u003eRM-306\u003c\/a\u003e – Six relay adder module\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-twelve-relay-circuit-adder-module\"\u003eRM-312\u003c\/a\u003e – Twelve relay adder module\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-pr-300-polarity-reversal-city-tie-module\"\u003ePR-300\u003c\/a\u003e – Polarity reversal \/ city tie module\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-remote-trouble-indicator\"\u003eRTI-1\u003c\/a\u003e – Remote trouble indicator\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-mircom-ram-1000-led-remote-annunciator\"\u003eRAM-1032TZDS\u003c\/a\u003e – Remote LED annunciator\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/steel-fire-semi-flush-backbox-for-series-1000-annunciators\"\u003eBB-1001D\u003c\/a\u003e – Annunciator backbox\u003c\/li\u003e\n\u003cli\u003eCFG-300 – Configuration tool\u003c\/li\u003e\n\u003cli\u003eMP-320R – Solenoid end-of-line module\u003c\/li\u003e\n\u003cli\u003eOCAC-302 – Output Class A converter\u003c\/li\u003e\n\u003cli\u003eBC-160 – External battery cabinet\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv data-sn=\"specs\"\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003ctd\u003eReleasing Control Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eMircom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMfr. Model #\u003c\/th\u003e\n\u003ctd\u003eFR-320-R, FR-320-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eApplications\u003c\/th\u003e\n\u003ctd\u003eDeluge, pre-action, agent release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInputs\u003c\/th\u003e\n\u003ctd\u003e6, Class B (Style B); Class A via ICAC-306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOutputs\u003c\/th\u003e\n\u003ctd\u003e4 Class B (Style Y), 1.7 A each, 5 A total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReleasing Circuits\u003c\/th\u003e\n\u003ctd\u003eOutputs 3 and 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e4-Wire Smoke Power\u003c\/th\u003e\n\u003ctd\u003e22.3 VDC, 300 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBattery Space\u003c\/th\u003e\n\u003ctd\u003eUp to 12 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRelease Timer\u003c\/th\u003e\n\u003ctd\u003e0 to 60 s (5 s steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSoak Timer\u003c\/th\u003e\n\u003ctd\u003e0 to 15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (W x H x D)\u003c\/th\u003e\n\u003ctd\u003e14.5 x 20 x 4.5 in., less trim ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDoor Colours\u003c\/th\u003e\n\u003ctd\u003eRed (FR320R), White (FR320W); black backbox\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eListings\u003c\/th\u003e\n\u003ctd\u003eUL 864 10th ed., ULC-S527 4th ed.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003c\/div\u003e\u003cdiv data-sn=\"literature\"\u003e\n\u003ch3\u003eDocuments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/9387\/2943\/files\/mircom-fr-320-catalogue-sheet.pdf?v=1795485941\" target=\"_blank\" rel=\"noopener\"\u003eMircom FR-320 Series Catalogue Sheet (CAT-5664) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0061\/9387\/2943\/files\/mircom-fr-320-installation-manual.pdf?v=1795485941\" target=\"_blank\" rel=\"noopener\"\u003eMircom FR-320 Installation and Operation Manual (LT-951) (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Steel Fire Equipment Ltd","offers":[{"title":"Red","offer_id":67804843442425,"sku":"FR320R","price":2256.63,"currency_code":"CAD","in_stock":true},{"title":"White","offer_id":67804843475193,"sku":"FR320W","price":2230.4,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0061\/9387\/2943\/files\/fr320r.png?v=1795471112"}],"url":"https:\/\/www.supplynow.ca\/collections\/fire-alarm-control-panels.oembed","provider":"Supplynow Limited","version":"1.0","type":"link"}